Remote Display

<< Click to Display Table of Contents >>

Navigation:  LCR-II Product Manual > Installation >

Remote Display

LectroCount Remote Display - Auxiliary Outputs 4 & 5

Auxiliary outputs 4 and 5 are typically used for the 2¼" E1610 Large Remote Display, but they can also be used with other types of displays. Signals from these outputs duplicate the volume data sent to the LCR-II display.

 

Refer to the LectroCount remote display manual for complete installation instructions.

 

To wire the 2¼" E1610 Large Remote Display to the LCR-II:

1.Attach cable glands and/or conduit connectors to the display and the LCR-II port(s).

2.Thread the wires through a piece of weatherproof conduit cut-to-length from the display port to a LCR-II port.

3.Run the weatherproof conduit between the display and the LCR-II housing, pull the wires through the ports, and tighten the connectors.

4.Connect the four display terminals to four terminals on the J18 terminal block of the LCR-II CPU board.

Remote display terminal 20 to LCR-II terminal 45

Remote display terminal 21 to LCR-II terminal 39

Remote display terminal 22 to LCR-II terminal 40

Remote display terminal 23 to LCR-II terminal 41

 

remote_1