LC MA-Series® Meters

Liquid Controls positive displacement MA-series class 10 and class 12 meters are the industry standard for safe and accurate transfer of LPG and NH3 gases and liquids.

Simplicity of design and construction, together with sustained accuracy is why customers prefer Liquid Controls meters for the delivery and transfer of liquified petroleum gases throughout the world.

COMMON CONFIGURATIONS

FEATURES
  • Sustained Accuracy — no metal-to-metal contact inside the measuring chamber means minimal deterioration in accuracy over time, fewer recalibrations, and longer service life.
  • Meters conform to NIST and International Weights and Measures accuracy requirements.
  • Wide Temperature Range — products can be metered accurately from -40° F (-40° C) to 160° F (71°C).
  • Wide Viscosity Range — LC meters can accurately meter products from less than 30 SSU (less than 1 centipoise) to 1,500,000 SSU (325,000 centipoise).
  • Maximum Adaptability — right angle design with choice of stock or custom elbows/ fittings provides unequaled mounting flexibility to meet your installation requirements.
  • High Pressure rating — Rated to 350psi / 24 BAR.
OPTIONS & ACCESSORIES
  • Seals: Buna
  • End Fittings: NPT, BSPT, WELD “MA-Series”, 300lb ANSI “MSA-Series”
  • Registration (Electronic, Pulse Output or Mechanical)
  • Temperature Compensation (TVC)
  • Strainers
  • Vapor Eliminators
  • Printers
  • Valves
  • Pulsers
SPECS CHARTS
ACCURACY
  • Repeatability:  Capable of 0.02% or better at any flow rate over entire range
  • Linearity:
    • Over 5:1 range
      Mech. registration: capable of ±0.125% or better from max. nom. flow rate
      Elect. registration: capable of ±0.10% or better from max. nom. flow rate
    • Over 10:1 range
      Mech. registration: capable of ±0.22% or better from max. nom. flow rate
      Elect. registration: capable of ±0.10% or better from max. nom. flow rate
    • Over 40:1 range
      Mech. registration: capable of ±0.5% or better from max. nom. flow rate
      Elect. registration: capable of ±0.15% or better from max. nom. flow rate
  • Temperature range:
    -40º F to 160º F (-40º C to 71º C)
Stated accuracy obtainable when all variables remain constant. Reading/ measurements reflect a minimum of one minute of flow at selected rate(s). All accuracy statements based on metering safety solvent (aliphatic hydrocarbon), approximate viscosity 1 CPS. On higher viscosity products, the average deviation in accuracy will be less.

METER SPECS BY MODEL

MA-4®

MA-4® meters are used in low flow LPG applications such as dispensing and bottle filling of LPG gasses.

Meter Class Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon

MA-4® Specs MS150-04V_(MA4 Delivery Vehicles)  MS150-04D_(MA4 Dispenser)

  • Rating: 30 GPM (114 LPM), 350 psi (24.1 bar, 2414 kPa)
  • Flange: 1?
  • Meter Construction: Aluminum
  • Seals: Buna N
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)
MA-5®

MA-5® meters are used in lower flow LPG applications.

Meter Class Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon

MA-5® Specs MS150-05_(MA5)

  • Rating: 60 GPM (227 LPM), 350 psi (24 bar, 2414 kPa)
  • Flange: 1.5?, 2?
  • Meter Construction: Aluminum
  • Seals: Buna N
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)

MA-7®

MA-7® meters are most commonly used truck based (bobtail) LPG delivery applications as well as anhydrous ammonia.

Meter Classes Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon
12 Anhydrous Ammonia (NH3) Carbon

MA-7® Specs MS150-07_(MA7)

  • Rating: 100 GPM (378 LPM), 350 psi (24 bar, 2414 kPa)
  • Flange: 2?
  • Meter Construction: Aluminum
  • Seals: Buna N, (EPDM class 12)
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)

MA-15®

MA-15® meters are used in LPG bulk metering applications.

Meter Class Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon
12 Anhydrous Ammonia (NH3) Carbon

MA-15® Specs MS150-15_(MA15)

  • Rating: 200 GPM (756 LPM), 350 psi (24 bar, 2414 kPa)
  • Flange: 3? (or 3? in and 2?out)
  • Meter Construction: Aluminum
  • Seals: Buna N, (EPDM for class 12)
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)

METER SPECS BY MODEL

MA-4®

MA-4® meters are used in low flow LPG applications such as dispensing and bottle filling of LPG gasses.

Meter Class Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon

MA-4® Specs

  • Rating: 30 GPM (114 LPM), 350 psi (24.1 bar, 2414 kPa)
  • Flange: 1?
  • Meter Construction: Aluminum
  • Seals: Buna N
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)
  • Hazardous Location Rating: Class 1, Division I, Group D (LPG)
  • Enclosure: NEMA 4X
  • Safety: NFPA 58, UL 25
MA-5®

MA-5® meters are used in lower flow LPG applications.

Meter Class Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon

MA-5® Specs

  • Rating: 60 GPM (227 LPM), 350 psi (24 bar, 2414 kPa)
  • Flange: 1.5?, 2?
  • Meter Construction: Aluminum
  • Seals: Buna N, Viton
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)
  • Hazardous Location Rating: Class 1, Division I, Group D (LPG)
  • Enclosure: NEMA 4X
  • Safety: NFPA 58, UL 25

MA-7®

MA-7® meters are most commonly used truck based (bobtail) LPG delivery applications as well as anhydrous ammonia.

Meter Classes Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon
12 Anhydrous Ammonia (NH3) Carbon

MA-7® Specs

  • Rating: 100 GPM (378 LPM), 350 psi (24 bar, 2414 kPa)
  • Flange: 2?
  • Meter Construction: Aluminum
  • Seals: Buna N, Viton
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)
  • Hazardous Location Rating: Class 1, Division I, Group D (LPG)
  • Enclosure: NEMA 4X
  • Safety: NFPA 58, UL 25

MA-15®

MA-15® meters are used in LPG bulk metering applications.

Meter Class Description Bearing Material
10 Liquified petroleum gas (LPG) such as propane Carbon

MA-15® Specs

  • Rating: 200 GPM (756 LPM), 350 psi (24 bar, 2414 kPa)
  • Flange: 3? (or 3? in and 2?out)
  • Meter Construction: Aluminum
  • Seals: Buna N, Viton
  • Maximum Pressure: 350 psi (as listed by catalog number)
  • Temperature: -40° to 160° F (-40° to 71.1° C)
  • Hazardous Location Rating: Class 1, Division I, Group D (LPG)
  • Enclosure: NEMA 4X
  • Safety: NFPA 58, UL 25